PSRUI Guide
Processing Inspector
What the Zap, Pam, TOA, Cal, and Batch tabs do and how they map to the backend workflow.
The Processing Inspector is the center of PSRUI's processing workflow.
It does not edit charts directly. Instead, it updates the active session recipe and refreshes the preview.
Zap
- operates on the
Freq x Phasewaterfall - supports single-channel clicks and box selection
- v1 is limited to channel zapping
Pam
- controls
dedisperse - controls
tscrunch,fscrunch, andbscrunch - controls
phase rotate
These transforms first affect the preview. Export then applies the same recipe to a new output file.
TOA
- choose a template archive
- choose
PGS,GIS,PIS,SIS, orZPS - choose
tempo2orparkesoutput format - inspect raw
patoutput and a residual preview
PSRUI today: this is a
pat-based v1 workflow, not yet a fulltempo2timing-residual interface.
Cal
- accepts a calibration search path,
database.txt, or a solution file - previews the
paccommand and log output - updates the active session preview
Batch
- save and load recipes
- define archive naming and output directories
- optionally export TOA text alongside archives
Continue with Batch and Export.